Home /

Doppler Fixed Clamp On Ultrasonic Flow Meters By Sound Wave To Determine

Send your message to this supplier
*From:
Your email address is incorrect!
To:Shanghai Xunhui Environment Technology Co., Ltd.
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap Doppler Fixed Clamp On Ultrasonic Flow Meters By Sound Wave To Determine Velocity Of Waste Water from wholesalers
  • Buy cheap Doppler Fixed Clamp On Ultrasonic Flow Meters By Sound Wave To Determine Velocity Of Waste Water from wholesalers
  • Buy cheap Doppler Fixed Clamp On Ultrasonic Flow Meters By Sound Wave To Determine Velocity Of Waste Water from wholesalers
  • Buy cheap Doppler Fixed Clamp On Ultrasonic Flow Meters By Sound Wave To Determine Velocity Of Waste Water from wholesalers

Doppler Fixed Clamp On Ultrasonic Flow Meters By Sound Wave To Determine Velocity Of Waste Water

Ask Latest Price
Brand Name:Purescience
Model Number:YE-TUF2000FC
Certification:ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Price:USD150-USD900
Supply Ability:500 sets per month
Delivery Time:3 weeks
Company Data
Active Member
Contact Person Murphy
Business Type: 86-21-67627650
Business Type: Manufacturer Distributor/Wholesaler Trading Company
Officials: Room 811 Build 143, No. 1399 Husong Road, Shanghai, China
Quality: Quality Certifitation Available
Product Details Company Profile
Product Details

Doppler Fixed clamp on ultrasonic flowmeter by sound wave to determine velocity of waste water | mining | metals


Generals

The transit time ultrasonic flowmeters, that the fluid to be measured, which can adequately conduct ultrasonic waves, the flowmeter won't measure in case the ultrasonic waves cannot penetrate the flow stream between the transducers. Vice versa, ultrasonic waves must be able to penetrate the fluid for Doppler flowmeters to operate accurately. When the fluid is relatively opaque and does not penetrate the fluid, Doppler flowmeters tend to measure the velocity of the fluid at or near the pipe wall, which can cause significant measurement error and/or cause the flowmeter to fail.


Data sheet

Contents

Parameter and performance

Convertor

Work Principle

ultrasonic flow meter, Transit-time

Precision

1%

Operation

key button, 4

signal output

single channel 4-20mA, resistance 0-1K , accuracy 0.1%

single way OCT pulse (Pulse width: 6-1000ms, default: 200ms)

single channel relay output

signal input

Tri way 4-20mA, accuracy: 0.1%, (temp., pressure, level)

the temperature transducer Pt100, heat / energy measurement

Interface

Galvanic isolation RS485, software upgrade by PC, MODBUS

Special cable

Paired cable in twisted, 50m; RS485, transmission distance 1000m or above.

Port connect

Material

carbon steel, stainless, cast iron, copper, cement, PVC, aluminum, etc

Diameter

DN15 - DN6000 mm

Pipe straight

the upstream: 10xDia, the downstream: 5xDia, and 30xDia from pump

Measurement

Liquid media

Single sonic wave transmittable liquid, such as municipal water, cooling

water, seawater water, waste water, pure water, Sewage with particle content, such

as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals,

heating, ventilation ,air conditioner, power plants,


Temperature

-30-160℃


Turbidity

Up to 10000 ppm and less bubble


Flow velocity

0-7 m/s

Work environment

Temperature

Convertor: -20-60 ℃, Transducer: -30-160℃

Humidity

Convertor: 85%RH, Transducer: submersible up to depth 2m

Power supply

DC8-36V or AC10-30V / 1.5W

Dimension

Convertor: 95*95*35mm


How to use:

The ultrasonic flowmeters are popularly used in the measurement of the velocity of liquids that allow ultrasonic waves to pass, such as water, molten sulfur, cryogenic liquids, and chemicals. The transit time designs are also available to measure gas and vapor flow. Since fluids that do not pass ultrasonic energy, such as many types of slurry, limit the penetration of ultrasonic waves into the fluid. For the doppler ultrasonic flowmeters, the opaque liquids can limit ultrasonic wave penetration too near the pipe wall, that can decrease accuracy and/or cause the flowmeter to fail to measure. The transit time ultrasonic flowmeters may fail to operate when an opaque liquid weakens the ultrasonic wave to such an extent that the wave does not reach the receiver.


Metering Diagram


Flow measurement Heat measurement

Doppler Fixed Clamp On Ultrasonic Flow Meters By Sound Wave To Determine Velocity Of Waste Water

Reference chart

Type

Model

Pipe dia (mm)

Temperature

Dimension (mm)

Clamp on

TS-2

DN15-100

-30-90℃

45x25x32

TM-1

DN50-700

-30-90℃

64x39x44

TL-1

DN300-6000

-30-90℃

97x54x53

Clamp on (high temperature)

TS-2-HT

DN15-100

-30-90℃

45x25x32

TM-1-HT

DN50-700

-30-90℃

64x39x44

TL-1-HT

DN300-6000

-30-90℃

97x54x53

Insertion type

TC-1

DN80-6000

-30-90℃

190x80x55

TC-2(lengthen)

DN80-6000

-30-90℃

335x80x55

Pipe type

G3 (π type)

DN15-25

-30-160℃


G2

DN32/DN40

-30-160℃


G3

DN50-6000

-30-160℃



Optional temperature transducer

Specification

Model

Dia

Temp.

Water cut

Accuracy

Clamp-on temp. transducer Pt100

CT-1

>DN50

-40-160℃

No

100+ 0.8℃

Insertion temp. Transducer Pt100

TCT-1

Yes

Insertion temp. Pt100 with pressure

PCT-1

No

Insertion temp.Pt100 for small pipe D

SCT-1

<DN50

Yes


Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Applications

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

I

Model









YF

Electromagnetic flowmeter


TF

Turbine


VF

Votex


LX

Vane wheel


T

Ultrasonic



E/F display mode

E: compact/local display, F: remote display




Pipe Dia

Type (mm)




xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

400, 500, 600, 800, 1000




Code

Accuracy




1

+ 0.5% FS




2

+ 1.0% FS




3

+ 0.2% FS





Code

Type





N

Converter: 12 / 24 VDC, pulse output





A

Transmitter: 24VDC, 4-20mA outpt





B

Intelligent, Lion battery, no local display





G

Smart, local display, 4-20mA output





C1

Smart, local display, RS485





C2

Smart, local display, HART






Code

Type






S

Carbon steel housing






L

Stainless steel housing






G

High pressure housing






HL

316L electrode






HTi

Titanium electrode






HTa

Tantlum electrode






HC

Hastelloy-C electrode






L1

Liquid media






L2

Gas media






P

Pressure compensation






T

Temperature compensation






PT

Pressure&Temp. Compensation






F

PTFE liner






X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F,

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

RS485, 316L electrode, liquid media meter, PTFE liner


Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Calibration

Doppler Fixed Clamp On Ultrasonic Flow Meters By Sound Wave To Determine Velocity Of Waste Water

Work shop

Doppler Fixed Clamp On Ultrasonic Flow Meters By Sound Wave To Determine Velocity Of Waste Water

Company Profile

Shanghai Xunhui Environment Technology Co., Ltd.

Focus on low-carbon energy and environment protection technology, we design and manufacture fluid processing and control products to give our contribution to the sustainable energy develop.

 

Lots of mega projects have been installed with our products, Shanghai expo center, Shanghai Disney energy center, Beijing Z15 tower, Malaysia GDC energy station, etc. Our technology and practical application experience, allow us to provide our client with products and solutions which meet your expectation on building, improving and mainting equipment. The industries we served:

 

  • New energy
  • Petroleum and chemical
  • Industrial energy
  • Oil and gas
  • Metals and mining
  • Pulp and paper
  • Water and waste water treatment
  • Marine
  • Power
  • Refining
  • Food and beverage
  • Life sciences

 

Our R&D, customer experience and manufacturing center is located in the “Low energy building science center” Hanghzou, China. As a Provincial class Postdoctoral workstation by collaboration with China State Energy research institute, which ensure our advantage from technician, science research & development, equipment. Our main products includes: flowmeters, roots air blower, pump, as well as design consultancy on RO, UF, NF design.

 

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Shanghai Xunhui Environment Technology Co., Ltd.

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China Transit Time Fixed Insertion Ultrasonic Magnetic Flow Meter For Slurry / Sewage wholesale

Transit Time Fixed Insertion Ultrasonic Magnetic Flow Meter For Slurry / Sewage

China Open Channel Ultrasonic Magnetic Flow Meter For Sewage / Waste Water Treatment 600 m3 / H Converter wholesale

Open Channel Ultrasonic Magnetic Flow Meter For Sewage / Waste Water Treatment 600 m3 / H Converter

China 10m/S 40mm PN16 RS485 Ultrasonic Water Meter Brass Pipe wholesale

10m/S 40mm PN16 RS485 Ultrasonic Water Meter Brass Pipe

China Insert doppler Ultrasonic Flow meter for volume flow measurement wholesale

Insert doppler Ultrasonic Flow meter for volume flow measurement

China Residential Water Ultrasonic Flow Meters Convectional Type Pn16 Pressure wholesale

Residential Water Ultrasonic Flow Meters Convectional Type Pn16 Pressure

China Portable Ulstrasonic Magnetic Flow Meter For Volumetric Measurement Non Contact Corrosion Resistance wholesale

Portable Ulstrasonic Magnetic Flow Meter For Volumetric Measurement Non Contact Corrosion Resistance

China Residential Inline Ultrasonic Flow Meters LCD Irrigation Mass Flow Measurement wholesale

Residential Inline Ultrasonic Flow Meters LCD Irrigation Mass Flow Measurement

China GPRS Wireless Ultrasonic Water Meter , Convectional Type DN25 Brass Tube R500 wholesale

GPRS Wireless Ultrasonic Water Meter , Convectional Type DN25 Brass Tube R500

China Irrigation DN50 PN16 Strap On Ultrasonic Flow Meters wholesale

Irrigation DN50 PN16 Strap On Ultrasonic Flow Meters

China AMR IP67 1.8NM Torque DC3.6V Electric Valve Actuator wholesale

AMR IP67 1.8NM Torque DC3.6V Electric Valve Actuator

China HVAC DN20mm 2 Way 4.5NM Torque DC Valve Actuator wholesale

HVAC DN20mm 2 Way 4.5NM Torque DC Valve Actuator

Inquiry Cart 0