Significance and Use
This test method provides a disturbed soil sample for moisture
content determination, for identification and classification
(Practices D 2487 and D 2488) purposes, and for laboratory tests
appropriate for soil obtained from a sampler that will produce
large shear strain disturbance in the sample such as Test Methods D
854, D 2216, and D 6913. Soil deposits containing gravels, cobbles,
or boulders typically result in penetration refusal and damage to
the equipment.
This test method provides a disturbed soil sample for moisture
content determination and laboratory identification. Sample quality
is generally not suitable for advanced laboratory testing for
engineering properties. The process of driving the sampler will
cause disturbance of the soil and change the engineering
properties. Use of the thin wall tube sampler (Practice D 1587) may
result in less disturbance in soft soils. Coring techniques may
result in less disturbance than SPT sampling for harder soils, but
it is not always the case, that is, some cemented soils may become
loosened by water action during coring; see Practice D 6151, and
Guide D 6169.
This test method is used extensively in a great variety of
geotechnical exploration projects. Many local correlations and
widely published correlations which relate blow count, or N-value,
and the engineering behavior of earthworks and foundations are
available. For evaluating the liquefaction potential of sands
during an earthquake event, the N-value should be normalized to a
standard overburden stress level. Practice D 6066 provides methods
to obtain a record of normalized resistance of sands to the
penetration of a standard sampler driven by a standard energy. The
penetration resistance is adjusted to drill rod energy ratio of 60
% by using a hammer system with either an estimated energy delivery
or directly measuring drill rod stress wave energy using Test
Method D 4633.
Note 1—The reliability of data and interpretations generated by
this practice is dependent on the competence of the personnel
performing it and the suitability of the equipment and facilities
used. Agencies that meet the criteria of Practice D 3740 generally
are considered capable of competent testing. Users of this practice
are cautioned that compliance with Practice D 3740 does not assure
reliable testing. Reliable testing depends on several factors and
Practice D 3740 provides a means of evaluating some of these
factors. Practice D 3740 was developed for agencies engaged in the
testing, inspection, or both, of soils and rock. As such, it is not
totally applicable to agencies performing this practice. Users of
this test method should recognize that the framework of Practice D
3740 is appropriate for evaluating the quality of an agency
performing this test method. Currently, there is no known
qualifying national authority that inspects agencies that perform
this test method.
1. Scope
1.1 This test method describes the procedure, generally known as
the Standard Penetration Test (SPT), for driving a split-barrel
sampler to obtain a representative disturbed soil sample for
identification purposes, and measure the resistance of the soil to
penetration of the sampler. Another method (Test Method D 3550) to
drive a split-barrel sampler to obtain a representative soil sample
is available but the hammer energy is not standardized.
1.2 Practice D 6066 gives a guide to determining the normalized
penetration resistance of sands for energy adjustments of N-value
to a constant energy level for evaluating liquefaction potential.
1.3 Test results and identification information are used to estimate subsurface conditions for foundation design.
1.4 Penetration resistance testing is typically performed at 5-foot
depth intervals or when a significant change of materials is
observed during drilling, unless otherwise specified.
1.5 This test method is limited to use in nonlithified soils and
soils whose maximum particle size is approximately less than
one-half of the sampler diameter.
1.6 This test method involves use of rotary drilling equipment
(Guide D 5783, Practice D 6151). Other drilling and sampling
procedures (Guide D 6286, Guide D 6169) are available and may be
more appropriate. Considerations for hand driving or shallow
sampling without boreholes are not addressed. Subsurface
investigations should be recorded in accordance with Practice D
5434. Samples should be preserved and transported in accordance
with Practice D 4220 using Group B. Soil samples should be
identified by group name and symbol in accordance with Practice D
2488.
1.7 All observed and calculated values shall conform to the
guidelines for significant digits and rounding established in
Practice D 6026, unless superseded by this test method.
1.8 The values stated in inch-pound units are to be regarded as
standard, except as noted below. The values given in parentheses
are mathematical conversions to SI units, which are provided for
information only and are not considered standard.
1.8.1 The gravitational system of inch-pound units is used when
dealing with inch-pound units. In this system, the pound (lbf)
represents a unit of force (weight), while the unit for mass is
slugs.
1.9 Penetration resistance measurements often will involve safety planning, administration, and documentation. This test method does not purport to address all aspects of exploration and site safety. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Performance of the test usually involves use of a drill rig; therefore, safety requirements as outlined in applicable safety standards (for example, OSHA regulations, NDA Drilling Safety Guide, drilling safety manuals, and other applicable state and local regulations) must be observed.
2. Referenced Documents (purchase separately)
ASTM Standards
D653 Terminology Relating to Soil, Rock, and Contained Fluids
D854 Test Methods for Specific Gravity of Soil Solids by Water Pycnometer
D1587 Practice for Thin-Walled Tube Sampling of Fine-Grained Soils for Geotechnical Purposes
D2216 Test Methods for Laboratory Determination of Water (Moisture) Content of Soil and Rock by Mass
D2487 Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)
D2488 Practice for Description and Identification of Soils (Visual-Manual Procedure)
D3550 Practice for Thick Wall, Ring-Lined, Split Barrel, Drive Sampling of Soils
D3740 Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
D4220 Practices for Preserving and Transporting Soil Samples
D4633 Test Method for Energy Measurement for Dynamic Penetrometers
D5434 Guide for Field Logging of Subsurface Explorations of Soil and Rock
D5783 Guide for Use of Direct Rotary Drilling with Water-Based Drilling Fluid for Geoenvironmental Exploration and the Installation of Subsurface Water-Quality Monitoring Devices
D6026 Practice for Using Significant Digits in Geotechnical Data
D6066 Practice for Determining the Normalized Penetration Resistance of Sands for Evaluation of Liquefaction Potential
D6151 Practice for Using Hollow-Stem Augers for Geotechnical Exploration and Soil Sampling
D6169 Guide for Selection of Soil and Rock Sampling Devices Used With Drill Rigs for Environmental Investigations
D6286 Guide for Selection of Drilling Methods for Environmental Site Characterization
D6913 Test Methods for Particle-Size Distribution (Gradation) of Soils Using Sieve Analysis
Keywords
Penetration Resistance - Physical Properties - Samplers - Soil And Rocks Sampling - Soil Sampling - Soils - Split Barrel Samplers - Standard Penetration Test
ICS Code
ICS Number Code 93.020 (Earth works. Excavations. Foundation construction. Underground works)
UNSPSC Code
UNSPSC Code 11111501(Soil); 41113821(Soil penetration tester)
For more information, please contact:
ROSCHEN INC.
ROSCHEN GROUP LIMITED
ROSCHEN HOLDINGS LIMITED
Skype: ROSCHEN.TOOL , ROSCHEN_GROUP
WeChat: +86-137 6419 5009 ; +86-135 8585 5390
WhatsApp: +86-137 6419 5009 ; +86-135 8585 5390
Email: roschen@roschen.com ; roschen@roschen.net
Website: http://www.roschen.com ; http://www.roschen.net
ROSCHEN GROUP
ROSCHEN GROUP
ROSCHEN Group has the world class advanced equipment like 12000 tons forging, metal processing plant, heat treatment workshop, numerical control plant, Advanced five-axis machining center, etc. professional technical and skilled team to ensure mining, mineral tools, equipment products quality stable and reliable.
ROSCHEN Group Limited is a manufactory with years of research and development for the mining, mineral tools, equipment. We are capability to produce high performance world class products and control excellent quality. Our main product includes tricone bit, diamond core bits, drill pipe, core barrel, TCI tricone bit, mill tooth tricone bit, RC hammer, DTH bit, etc.
ROSCHEN Manufactory PROCESS
ROSCHEN Sales Value Growing Up!
ROSCHEN'S MISSION
1. Strive to create and supply Best quality products for the industry that last longer than the average products.
2. Provide excellent service for our clients. 24 hour-7 days /week schedule to get our clients what they need – FAST.